JWP

Windposts JWP are installed at intervals of no more than 750 mm and no more than 375 mm from the edge or corner. They are available in stainless steel Lean Duplex. The design load qR,d is 0.75 kN/m. The distance between the windposts in m is calculated from the quotient of qR,d in kN/m and the existing wind load wE,d in kN/m2 according to DIN EN 1991-1-4NA. The facing masonry and the windposts are connected using JMA brick tie anchors.