Windposts JWP are installed at intervals of no more than 750 mm and no more than 375 mm from the edge or corner. They are available in stainless steel Lean Duplex. The design load qR,d is 0.75 kN/m. The distance between the windposts in m is calculated from the quotient of qR,d in kN/m and the existing wind load wE,d in kN/m2 according to DIN EN 1991-1-4NA. The facing masonry and the windposts are connected using JMA brick tie anchors.
data sheetTender text
You can find the appropriate tender text for this product on these portals:
Products
Products | H installation height | BP profile width | HP profile height | t material thickness | W Weight per storage unit | bookmark |
---|---|---|---|---|---|---|
JWP-2500 | 2500 mm | 60 mm | 75 mm | 3 mm | 10,590 kg | |
JWP-2750 | 2750 mm | 65 mm | 75 mm | 3 mm | 12,600 kg | |
JWP-3000 | 3000 mm | 65 mm | 75 mm | 4 mm | 18,140 kg | |
JWP-3250 | 3250 mm | 70 mm | 80 mm | 4 mm | 21,170 kg | |
JWP-3500 | 3500 mm | 75 mm | 85 mm | 4 mm | 24,420 kg | |
JWP-3750 | 3750 mm | 80 mm | 90 mm | 4 mm | 27,910 kg | |
JWP-4000 | 4000 mm | 85 mm | 95 mm | 4 mm | 31,650 kg |