Wide-span cable tray, additional transverse rigidity due to welded and ripped inlay sheet. Electrical conductivity tested according to DIN EN 61537.
data sheet Assembly Instruction![Do not walk upon!](/fileadmin/_processed_/a/c/csm_symbol_begehen_verboten_thumb_eec87c8b41.jpg)
![UL classified](/fileadmin/_processed_/3/8/csm_ul-klassifiziert_logo_thumb_26b7f2596d.jpg)
Continously hot galvanized (Sendzimir process) (DIN EN 10346)
height | width | length | t material thickness | A cross section area | QSKdistributed load control cable | weight | ||
---|---|---|---|---|---|---|---|---|
WPR 120-20S | 120 mm | 200 mm | 6000 mm | 1,50 mm | 196 cm² | 0,29 kN/m | 36,42 kg | |
WPR 120-30S | 120 mm | 300 mm | 6000 mm | 1,50 mm | 294 cm² | 0,44 kN/m | 42,10 kg | |
WPR 120-40S | 120 mm | 400 mm | 6000 mm | 1,50 mm | 392 cm² | 0,59 kN/m | 47,96 kg | |
WPR 120-50S | 120 mm | 500 mm | 6000 mm | 1,50 mm | 490 cm² | 0,74 kN/m | 53,84 kg | |
WPR 120-60S | 120 mm | 600 mm | 6000 mm | 1,50 mm | 588 cm² | 0,88 kN/m | 59,7 kg |
Hot-dip galvanized, according to BS 729 (DIN EN ISO 1461)
height | width | length | t material thickness | A cross section area | QSKdistributed load control cable | weight | ||
---|---|---|---|---|---|---|---|---|
WPR 120-20F | 120 mm | 200 mm | 6000 mm | 1,50 mm | 196 cm² | 0,29 kN/m | 38,97 kg | |
WPR 120-30F | 120 mm | 300 mm | 6000 mm | 1,50 mm | 294 cm² | 0,44 kN/m | 45,05 kg | |
WPR 120-40F | 120 mm | 400 mm | 6000 mm | 1,50 mm | 392 cm² | 0,59 kN/m | 51,32 kg | |
WPR 120-50F | 120 mm | 500 mm | 6000 mm | 1,50 mm | 490 cm² | 0,74 kN/m | 57,61 kg | |
WPR 120-60F | 120 mm | 600 mm | 6000 mm | 1,50 mm | 588 cm² | 0,88 kN/m | 63,88 kg |